KEEP-IT-KOOL A/C System Sealer... because you can't do a two can job with just ONE CAN!

Frequently Asked Questions

1) WHAT IS KEEP-IT-KOOL™ A/C SYSTEM SEALER?
The sealer is a unique two part process that will quickly seal leaks in both metal and rubber parts. It also contains a UV die that will expose large leaks that should be repaired mechanically.

2) HOW DOES IT WORK?
The Sealer is a revolutionary new moisture cure formula that will form a permanent seal on a leak. Under normal operating conditions, It travels throughout the a/c system as a liquid. When a sealed and pressurized system leaks, there is a drop in pressure at the point of the leak. That drop in pressure causes condensation to form. That condensation causes the KEEP-IT-KOOL™ A/C System Sealer to form a patch.

3) ONCE IT SEALS A LEAK, WHAT HAPPENS TO THE REST OF THE SEALER?
The remaining sealer continues to circulate throughout the system as a liquid.

4) WILL THE A/C SYSTEM SEALER WORK FOR MORE THAN ONE HOLE?
Yes. Each application of KEEP-IT-KOOL™ A/C System Sealer has enough material to seal several holes.

5) IS THE KEEP-IT-KOOL™ A/C SYSTEM SEALER ANYTHING LIKE A RADIATOR STOP LEAK?
No. Compounds added to a cooling system work on different principles. In some cases, they even form a thick enough sludge to not only stop leaks, but to restrict flow. The A/C System Sealer works on the basis of a moisture cure. That is, it remains liquid until it meets the condensation formed around a leak. That condensation or moisture causes the Sealer to “set” and form a solid patch. Once the patch is formed, any unused sealer continues to travel throughout the system as a liquid.

6) WILL KEEP-IT-KOOL™ A/C SEALER CLOG VALVES OR DAMAGE THE COMPRESSOR?
No. That’s because within the closed and charged a/c system, the sealer remains a liquid. In fact, it may even improve overall system performance because some of the additives in the formula act as lubricating and drying agents.

7) WHAT HAPPENS TO THE SEALER IF MY SYSTEM HAS TO HAVE THE REFRIGERANT RECOVERED?
The KEEP-IT-KOOL™ A/C System Sealer will separate with the oil during recovery of refrigerant. It will not contaminate refrigerants.

8) WHAT HAPPENS IN THE CASE OF A MASSIVE LEAK (LIKE COLLISION DAMAGE)?
The A/C Sealer will be discharged with the oil and refrigerant escaping from the system.

9) WILL THE KEEP-IT-KOOL™ SEALER WORK ON ALL SYSTEMS?
Yes, it will work on all automotive systems with R-134a refrigerant. It should not be used on stationary systems.

10) WILL KEEP-IT-KOOL™ SEALER SEAL ALL LEAKS?Not necessarily. Some leaks may be too large. Prior to installation, the a/c system should undergo a 5 minute vacuum test to qualify the system as a good candidate for sealing. (See installation instructions for test procedures) Large leaks that can not be sealed will be exposed because of the UV leak detection die included in the formula.

11) IS THE SEAL PERMANENT?
Yes. When the formula is cured, a permanent seal is formed over that hole. Caution should be used if a leak is in a component that is subjected to severe vibration or stress. In those cases, the sealer may patch the original leak or crack, but the severe conditions may cause the leak to expand and become too large to be sealed in this manner.

12) ARE THERE ANY OTHER PRECAUTIONS THAT SHOULD BE TAKEN?
Yes. For best performance, the Sealer should be installed into as dry a system as possible. Even though one of the additives acts as a drying agent, old driers or accumulators that are saturated with moisture can case the sealer to set around the desiccant bag. There is no harm to the system, however the sealer formula will be used up inside the drier instead of on leaks. For best results or for systems that you are unsure of, either install a new drier, and/or evacuate for extended period of time with a source of heat on the drier, in order to expell as much moisture as possible.

13) CAN I INSTALL KEEP-IT-KOOL™ INTO A SYSTEM THAT CURRENTLY DOES NOT HAVE A LEAK?
Yes. The A/C Sealer is an excellent preventative measure that should be installed after major repairs or component replacement. It will seal small leaks that can show up after a few weeks of driving, and will prevent costly customer come backs. In the event of large leaks, they will become exposed with the UV leak die included in the formula.

14) HOW IS KEEP-IT-KOOL™ A/C SYSTEM SEALER INSTALLED?
Installers should follow the instructions packaged with the Sealer. Using the special installation hose and valve, the sealer is installed after vacuum is pulled on the system. Then the system is charged with refrigerant through the installation hose, assuring that all of the formula is washed into the system.

15) HOW LONG DOES IT TAKE FOR THE SEALER TO WORK?
The Sealer will go to work immediately once the system is charged and running. It will take 5-10 minutes for the sealer to circulate throughout the entire system, but as soon as leak and moisture is encountered, the sealer will start to work.


DO YOU HAVE A QUESTION THAT WE HAVE NOT ANSWERED HERE?
You can e-mail us now! Buy this product now!

See more products from Keep-it-Kool.com

© Copyright 2000-2002; Mobilair 2000; All Rights Reserved